Example questions and answers
These answers came from the tool itself. Your AI app may word them differently, but the numbers will match the online calculator.
1. “What Marlee Float do I need for a 5-acre sediment basin in South Carolina?”
Using South Carolina’s standard of 3,600 cubic feet per acre, the basin needs 18,000 ft³ drained in 2 to 5 days (a peak flow of 3,600 to 9,000 cubic feet per day, or cfd). Three options fit:
- 4 in. Marlee Float, 2.0″ orifice (orange): 6,737 cfd, drains in 2.67 days (recommended)
- 3 in. Marlee Float, 2.0″ orifice (blue): 6,218 cfd, 2.89 days
- 2 in. Marlee Float, 2″ orifice (yellow): 5,159 cfd, 3.49 days
2. “Size a skimmer for a 10-acre basin in Texas.”
Texas uses 3,600 ft³ per acre with a 1.5 to 3 day drawdown, so 36,000 ft³ needs 12,000 to 24,000 cfd. Recommended: one 6 in. Marlee Float with a 3.5″ orifice (white), 21,233 cfd, 1.70 days. Other fits: 4 in. with 3.5″ orifice (1.71 days), 4 in. with 3.0″ orifice (2.34 days), and 3 in. with 3″ orifice (2.62 days).
3. “I have a 9,000 cubic foot pond in Georgia. Which float works?”
Georgia’s 1 to 3 day window means 3,000 to 9,000 cfd. Recommended: 4 in. Marlee Float with a 2.0″ orifice (orange), drains in 1.34 days. The 3 in. with 2.0″ orifice (1.45 days), 2 in. with 2″ orifice (1.74 days) and 3 in. with 1.5″ orifice (2.55 days) also fit.
4. “What about a 1-acre basin in North Carolina?”
No single skimmer in the chart drains 1,800 ft³ inside North Carolina’s 2 to 5 day window. Widen the drain-time range if your plan allows it, or use the online calculator to try other values. You can also contact us for help.
Engineer’s Pack request: “Send me the Marlee Float Engineer’s Pack. I’m Pat Smith, pat@example.com, Smith Engineering.”
Example output: “The engineer pack link was emailed. The files are not included in this result. Please check your junk or spam folder for the zip file.”
State standards are based on publicly available information and may differ from your local requirements. Always confirm with your state or MS4 (municipal separate storm sewer system).